Page 26 - ELICYLINDER-EC-IAI, CILINDRI ELETTRICI,
P. 26

Precautions for Installation
Overall
˜For vertical mounting, it is recommended to have the motor installed on top.
While installing the motor on the bottom will not cause problems during normal operation, after a long period of time the grease can separate, flow into the motor unit, and cause problems on rare occasions.
Slider, High Rigidity Slider, Radial Cylinder, Rod (GS4/GD4), Table
˜Keep the body installation surface and workpiece mounting surface flatness at 0.05mm/m or lower. Uneven flatness will increase the slider's sliding resistance and may cause malfunction.
Slider, High Rigidity Slider
˜While installation in side and ceiling mount orientations are possible, this may cause slack or misalignment in the stainless steel sheet. Continued use in these orientations can cause the stainless steel sheet to break. Please inspect it daily and adjust the sheet if any slack or misalignment is found.
Slider, Radial Cylinder
˜Since the actuator cannot be accurately positioned in the width direction when fixing with side blocks (foot bracket: FT), use positioning pins, etc.
To mount:
(1) Press the reference surface of the actuator against the positioning pin, etc.
(2) Maintaining the pressure, fix side block A on the opposite side.
(3) Finally, fix side block B on the pin side.
* Note that there may be cases where sufficient fastening force cannot be obtained when mounting with methods other than the
procedure above.
 Radial Cylinder
BA Side block Side block
Positioning pin Reference surface
˜When applying radial load/moment load, we recommend fixing the entire surface of the base bottom.
Front bracket fixing may cause deflection or reflexion throughout the product due to radial load/moment load, leading to vibration, shortened product life, or breakdown.
25