Page 119 - RoboCilindri, rcp2/rcp3, robocilindri, sinta,
P. 119

DimensionsCAD drawings can be downloaded from IAI website.2/3D CADRCP2 RoboCylinderSlider0 12−0.052−M5 depth 8254−M4 depth 8 (same with opposite side)2−3 +0.05 Depth 2.5 0(same with opposite side) 7679244Note:The holes in the slider shown above, other than tapped holes, are used to install the slider onto the actuator. They cannot be used as finger positioning holes.Use the key slots to position the fingers.Compatible ControllersWeight (kg)0.5www.robocylinder.deFor Special OrderCable joint connector*1+0.03ø3 0 Depth 2.5P. A- 9Type MiniStandardControllers IntegratedRod TypeMiniStandardControllers IntegratedTable/Arm /Flat TypeMini StandardGripper/ Rotary TypeLinear Motor TypeCleanroom TypeSplash-ProofControllersPMEC /AMECPSEP /ASEPROBO NETERC2 PCON ACON SCON PSEL ASEL SSEL XSELPulse MotorServo Motor (24V)Servo Motor (230V)Linear Motor* *1The opening side of the slider is the home position.The motor-encoder cable is connected here. See page A-39 for details on cables.5MAX 15 MIN 124 36742825 7 11.52236+0.053 0 Depth 2.5+0.03 50Secure at least 10035The RCP2 series actuators can operate with the controllers below. Select the controller according to your usage.NameSolenoid Valve TypeSplash–Proof Solenoid Valve TypePositioner TypeSafety–Compliant Positioner TypePulse Train Input Type (Differential Line Driver)Pulse Train Input Type (Open Collector)Serial Communication TypeField Network TypeProgram Control TypeExternal ViewModelPMEC–C–28PI–NP–2–2 PSEP–C–28PI–NP–2–0 PSEP–CW–28PI–NP–2–0 PCON–C–28PI–NP–2–0 PCON–CG–28PI–NP–2–0 PCON–PL–28PI–NP–2–0 PCON–PO–28PI–NP–2–0 PCON–SE–28PI–N–0–0 RPCON–28P PSEL–C–1–28PI–NP–2–0DescriptionEasy–to–use controller, even for beginnersOperable with same signal as solenoid valve. Supports both single and double solenoid types.No homing necessary with simple absolute type.Positioning is possible for up to 512 pointsPulse train input type with differential line driver supportPulse train input type with open collector supportDedicated to serial communicationDedicated to field networkProgrammed operation is possible Operation is possible on up to 2 axesMax. Positioning Points3 points512 points(−)64 points 768 points 1500 pointsInput VoltageAC115V AC230VDC24VPower Supply CapacitySee P4812A max.See Page→ P477→ P487→ P525→ P503 → P557* This is for the single-axis PSEL.1.534−M4 depth 6+0.03 2−ø3 0Depth 2.5 (same with opposite side)RCP2-GRM 340


































































































   117   118   119   120   121