Page 57 - ELICYLINDER-EC-IAI, CILINDRI ELETTRICI,
P. 57

 Dimensions
CAD drawings can be downloaded from our website. www.intelligentactuator.com
17 6
M10×1.25 Supplied hex nut
55 6
M42×1.5 Supplied front fixing nut
2D 3D
EC ELECYLINDER
*1 When the rod is returning to its home position, please be careful of interference from surrounding objects,
as it will travel until it reaches the M.E.
M.E: Mechanical end S.E: Stroke end
*2 The length of the actuator cable can be set to 5m as an option.
*3 The interface box relay section within the dashed line is not dust-proof or splash-proof.
*4 Make sure that the total length of the actuator cable and power I/O cable is 10m or less.
*5 The direction of width across flats varies depending on the product. Those flats cannot be used for
(82)
31.5
14 (width across flats)
18.6
3 M.E.*1
The orientation of
the width across
flat is indeterminable. *5
The angle of the greasing port is undefined
(19) 12.6
L
Weight (kg)
Stroke 50 W/o Brake 322 With Brake 362
A 205 B 97
100 150 372 422 412 462 255 305 147 197
200 250 472 522 512 562 355 405 247 297 2.4 2.6 2.7 2.9
63
Detailed view of Q (Greasing port shape)
Air intake/exhaust port Applicable tube O.D.: φ6
300 572 612 455 347 2.8 3.1
73
82
¢Dimensions and Mass by Stroke
W/o Brake 1.8 2.0 2.2 With Brake 2.1 2.3 2.5
Controller side Options/Accessories
Name
External view
Model
Overview
Touch Panel Teaching Pendant
£TB-02 (for wired connection only) £TB-03 (for wired/wireless connection)
PC software
24VDC power supply
£PS-241 (100V input) £PS-242 (200V input)
A 24VDC power supply that can instantaneously output up to 17A. Input voltage 200VAC and 100VAC specifications are available.
CAD
CAD
20 22
ST 64
3
S.E. Home M.E.*1
Supplied front fixing nut
Fitting rotation range
Arrow view V
Stroke +124
L A
B
Greasing port
(M4 same on opposite side)
Interface box dimensions
73 12
˜ TB-02
A teaching pendant equipped with functions such as start point, end point, and AVD input, trial operation, and monitoring.
˜TB-03
A data setter that supports wireless connection.
The start point, end point and AVD can be input with wireless connection.
£RCM-101-MW (RS232 connection version) £RCM-101-USB (USB connection version)
Software for start point input, end point input and AVD input, trial operation, and monitoring using a PC.
Both the RS232C version and USB version are available for PC connection.
* For system configurations using the above tools, refer to P.68.
(16)
18 Q
(2000)*2 Must be 100 or more.
Actuator cable
(29.5)
42 22
Stroke +123.5
(9.2)
2
7.5 (width across flats)
47.5
Greasing port
117 (W/o brake) 157 (With brake)
Actuator
cable connector
Power / I/O connector *4 Status LED
Teaching port
reference plane. Arrow view V
Interface box (33.5)
*3
2-R2.25
2-(R)
(φ32)
2-φ4.5
Actuator cable
connection hole
diameter: Must be φ18 or more
12.6
18.5
11 (4) 15
3
(3.3)
13.5
9.6
30
5 17
14.1
29 21.5 (3)27
33.5
(82)
64
14 (width across flats)
φ60 φ55
φ42
(57)
(19.6)
(12)
M42×1.5
φ25 (rod O.D.) M10×1.25
EC-R6£W 56
   55   56   57   58   59