Page 47 - ELICYLINDER-EC-IAI, CILINDRI ELETTRICI,
P. 47

 Dimensions
CAD drawings can be downloaded from our website. www.intelligentactuator.com
2D 3D
*1 *2
EC ELECYLINDER When the rod is returning to its home position, please be careful of interference from surrounding
objects, as it will travel until it reaches the M.E.
M.E: Mechanical end S.E: Stroke end
The direction of width across flats varies depending on the product. Those flats cannot be used for reference plane.
3.6
M6×1.0
Supplied hex nut
9.5 (Screweffective length)
ST
22
4 (width across flats) 16 8
1.5
18
17
4-M4 depth 8
0.5
12.5
Status LED
(11.5)
1
M.E.*1 S.E. 12 (width across flats)
The orientation of the width across flat is indeterminable. *2
Home
CAD
CAD
28
M.E.*1
L
Must be 100 or more. (1.3)
B
37
Teaching port
Power / I/O connector
3.5
17
78 25
41.1
25.4
φ24h7 M6×1.0
φ9- 0.1
10
L
B
Weight (kg)
W/o Brake With Brake W/o Brake With Brake W/o Brake With Brake
30 50 125 125 155 155 70 70 100 100 0.6 0.6 0.7 0.7
Encoder Type Stroke
Incremental
30 50 105 125 135 135 50 70 80 80 0.5 0.6 0.7 0.7
Battery-less Absolute
Name
External view
Model
Overview
Touch Panel Teaching Pendant
£TB-02 (for wired connection only) £TB-03 (for wired/wireless connection)
PC software
24VDC power supply
£PS-241 (100V input) £PS-242 (200V input)
25 34
23
M3 depth 8
(For ground connection)
26
¢Dimensions and Mass by Stroke
Controller side Options/Accessories
˜ TB-02
A teaching pendant equipped with functions such as start point, end point, and AVD input, trial operation, and monitoring.
˜TB-03
A data setter that supports wireless connection.
The start point, end point and AVD can be input with wireless connection.
Software for start point input, end point input and AVD input, trial operation, and monitoring using a PC.
Both the RS232C version and USB version are available for PC connection.
A 24VDC power supply that can instantaneously output up to 17A. Input voltage 200VAC and 100VAC specifications are available.
* For system configurations using the above tools, refer to P.68.
£RCM-101-MW (RS232 connection version) £RCM-101-USB (USB connection version)
EC-RP4 46


















   45   46   47   48   49